STANDARDS FOR THE MANAGEMENT OF USED OIL

Has used oil mixed with a listed hazardous waste been managed as a hazardous waste? [N.J.A.C. 7:26A-6.1(a)2i(1)]

Has used oil mixed with a characteristic hazardous waste been managed as a hazardous waste. [N.J.A.C. 7:26A-6.1(a)2ii(1)]

Did the used oil generator comply with the management requirements for diesel fuel mixed with used diesel crankcase oil. [N.J.A.C. 7:26A-6.1(a)4ii]

Did the marketer or burner comply with requirements of 40 C.F.R. 761.20(e) for used oil containing quantifiable levels of PCBs. [N.J.A.C. 7:26A-6.1(a)9]

Did used oil burned for energy recovery meet the specifications listed in N.J.A.C. 7:26A-6.2(a)? [N.J.A.C. 7:26A-6.2(a)]

Did the facility have a permit to construct, install or alter control apparatus or equipment and certificate to to operate control apparatus or equipment or other required authorization prior to burring on-specification used oil fuel? [N.J.A.C. 7:26A-6.2(b)]

Did the facility comply with the requirements for managing used oil in a surface impoundment or waste pile. [N.J.A.C. 7:26A-6.3(a)]

Was the used oil being used as a DUST SUPPRESSANT? [N.J.A.C. 7:26A-6.3(b)]

Did the burner burn off-specification used oil in a device other than an industrial furnace, industrial or utility boiler or hazardous waste incinerator, or fail to obtain a “Permit to Construct, Install or Alter Control Apparatus or Equipment and Certificate to Operate Control Apparatus” prior to burning off-specification used oil in one of these devices? [N.J.A.C. 7:26A-6.3(c)]

Did the facility comply with the prohibition against burning on-specification used oil fuel in either a residential or Category I institutional device, furnace or boiler? [N.J.A.C. 7:26A-6.3(d)]

Did the generator BURN on-specification used oil in a used oil-fired space heater designed to have a maximum capacity of not more than 0.5 million BTU per hour? [N.J.A.C. 7:26A-6.3(e)]

Did the generator BURN off-specification used oil in a space heater? [N.J.A.C. 7:26A-6.3(f)]

Did the used oil transporter conduct non-incidental processing of used oil? [N.J.A.C. 7:26A-6.6(b)]

USED OIL TRANSFER FACILITY REQUIREMENTS

Did the transporter comply with SPCC, Federal Clean Air Act and UST regulations? [N.J.A.C. 7:26A-6.6(f)1]

Did the transfer facility ensure that used oil was not stored for more than 35 days. [N.J.A.C. 7:26A- 6.6(f)2]

Did the used oil transporter or transfer facility store used oil in units subject to regulation under N.J.A.C. 7:26G. [N.J.A.C. 7:26A-6.6(f)3]

Did the used oil transporter ensure that the containers and aboveground tanks used to store used oil were in good condition or were not leaking? [N.J.A.C. 7:26A-6.6(f)4]

Were the containers used to store used oil equipped with secondary containment? [N.J.A.C. 7:26A-6.6(f)5]

Were existing aboveground tanks used to store used oil equipped with secondary containment? [N.J.A.C. 7:26A-6.6(f)6]

Were new aboveground tanks used to store used oil equipped with secondary containment? [N.J.A.C. 7:26A-6.6(f)7]

Were all units labeled or marked clearly with the words “Used Oil”. [N.J.A.C. 7:26A-6.6(f)8]

Did the transfer facility, upon detection of a release of used oil: a. Stop the release. b. Contain the released used oil. c. Clean up and manage properly the released used oil and other materials. d. If necessary, failed to repair or replace any leaking used oil storage containers or tanks prior to returning them to service. [N.J.A.C. 7:26A-6.6(f)9]

Was the used oil that was identified as a hazardous waste and could not be recycled, managed as a hazardous waste? [N.J.A.C. 7:26A-6.10(b)1]

All collected solid waste shall be properly deposited at an approved facility in accordance with N.J.A.C. 7:26-1 and 2. Solid waste or recyclable materials shall be deposited at a solid waste or recycling facility only to the extent the materials contained in an individual load are waste types and recyclables permitted for acceptance at that facility and commingled only to the extent permitted in the operating approvals for that facility. [N.J.A.C. 7:26- 3.4(b)]

Was used oil that was not hazardous waste and could not be recycled, managed as a solid waste? [N.J.A.C. 7:26A-6.10(b)2]

Was the used oil being used as a DUST SUPPRESSANT? [N.J.A.C. 7:26A-6.10(c)]

Was lawful entry and inspection allowed? [N.J.A.C. 7:26- 5.7(a)]
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][vc_empty_space][/vc_column][/vc_row]