{"id":1258,"date":"2022-05-05T14:41:36","date_gmt":"2022-05-05T18:41:36","guid":{"rendered":"https:\/\/deptest.nj.gov\/ghg\/?page_id=1258"},"modified":"2023-07-11T15:28:31","modified_gmt":"2023-07-11T19:28:31","slug":"natural-gas-public-utilities","status":"publish","type":"page","link":"https:\/\/deptest.nj.gov\/ghg\/ghgmr-rule\/natural-gas-public-utilities\/","title":{"rendered":"Requirements for Natural Gas Public Utilities with Distribution Systems"},"content":{"rendered":"<p>[vc_row full_width=&#8221;stretch_row_content_no_spaces&#8221; css=&#8221;.vc_custom_1677530790009{background-color: #ffffff !important;}&#8221;][vc_column][vc_single_image image=&#8221;1556&#8243; img_size=&#8221;full&#8221;][vc_raw_html]JTNDZGl2JTIwY2xhc3MlM0QlMjJjYXJvdXNlbC1jYXB0aW9uJTIwZC1tZC1ibG9jayUyMGQtc20tYmxvY2slMjIlM0UlMEElMjAlMjAlMjAlMjAlMjAlM0NoMSUzRUdSRUVOSE9VU0UlMjBHQVMlMjBNT05JVE9SSU5HJTIwQU5EJTIwUkVQT1JUSU5HJTIwUlVMRSUzQyUyRmgxJTNFJTBBJTNDJTJGZGl2JTNF[\/vc_raw_html][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1652362115516{background-color: #ffffff !important;}&#8221;][vc_column][breadcrumb-shortcode][vc_custom_heading text=&#8221;Natural Gas Public Utilities with Distribution Systems&#8221; font_container=&#8221;tag:h2|font_size:28|text_align:left|color:%2300669d&#8221; google_fonts=&#8221;font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:500%20bold%20regular%3A500%3Anormal&#8221;][vc_column_text]<span class=\"TextRun SCXW142758697 BCX0\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW142758697 BCX0\">The Department require<\/span><span class=\"NormalTextRun SCXW142758697 BCX0\">s<\/span><span class=\"NormalTextRun SCXW142758697 BCX0\"> each gas public utility operating within the State, and providing natural gas, to submit an annual Pipeline Modernization Report. <\/span><span class=\"NormalTextRun SCXW142758697 BCX0\">E<\/span><span class=\"NormalTextRun SCXW142758697 BCX0\">ach gas public utility will be required to include three categories of information in the Pipeline Modernization Report: general information about the mains and service lines in the State, leak monitoring information, and blowdown event information.<\/span><\/span><span class=\"EOP SCXW142758697 BCX0\" data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span>[\/vc_column_text][vc_separator][vc_custom_heading text=&#8221;Applicable Rules&#8221; font_container=&#8221;tag:h2|font_size:24|text_align:left|color:%23000000&#8243; google_fonts=&#8221;font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:500%20bold%20regular%3A500%3Anormal&#8221;][vc_column_text]Applicable Rules: <a href=\"https:\/\/deptest.nj.gov\/ghg\/wp-content\/uploads\/sites\/147\/njac7-27e.pdf\" target=\"_blank\" rel=\"noopener\">N.J.A.C. 7:27E<\/a> &#8211; Subchapter 3 REPORTING REQUIREMENTS FOR GAS PUBLIC UTILITIES[\/vc_column_text][vc_separator][vc_custom_heading text=&#8221;Record Keeping&#8221; font_container=&#8221;tag:h2|font_size:24|text_align:left|color:%23000000&#8243; google_fonts=&#8221;font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:500%20bold%20regular%3A500%3Anormal&#8221;][vc_column_text]1<sup>st<\/sup> Reporting year begins on July 1, 2022.<\/p>\n<p>1<sup>st<\/sup> Reporting year ends on December 31, 2022<\/p>\n<p>Subsequent reporting is conducted on a calendar year basis (January 1 \u2013 December 31)<\/p>\n<p>Reporting Fee = $8000 annually[\/vc_column_text][vc_separator][vc_custom_heading text=&#8221;What to report on&#8221; font_container=&#8221;tag:h2|font_size:24|text_align:left|color:%23000000&#8243; google_fonts=&#8221;font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:500%20bold%20regular%3A500%3Anormal&#8221;][vc_column_text]Submit a Pipeline Modernization Report by June 15, 2023, at <a href=\"https:\/\/nj.gov\/dep\/online\/\" target=\"_blank\" rel=\"noopener\">NJDEPonline.com<\/a> (available January 1, 2023). The gas public utility must annually report the following information:<\/p>\n<p>1. The miles of mains and number of service lines in New Jersey, identified by material type, in the distribution system at the end of the reporting period.<\/p>\n<p>2. Mains and service lines in New Jersey added, replaced, or refurbished in the reporting period, as follows:<\/p>\n<p style=\"padding-left: 40px;\">i. Miles of mains grouped by the original mains material type and the replacement or refurbished material type;<\/p>\n<p style=\"padding-left: 40px;\">ii. Number of service lines grouped by the original service line material type and the replacement or refurbished material type;<\/p>\n<p style=\"padding-left: 40px;\">iii. Miles of mains added, grouped by material type; and<\/p>\n<p style=\"padding-left: 40px;\">iv. Number of service lines added, grouped by material type.<\/p>\n<p>3. Identification of each leak from pipeline components that have a leak grade classification ranked as grade 1, 2, or 3, as follows:<\/p>\n<p style=\"padding-left: 40px;\">i. Leak identification number;<\/p>\n<p style=\"padding-left: 40px;\">ii. Pipeline component that is leaking or has leaked;<\/p>\n<p style=\"padding-left: 40px;\">iii. Grade classification of the leak;<\/p>\n<p style=\"padding-left: 40px;\">iv. Date that the leak is reported;<\/p>\n<p style=\"padding-left: 40px;\">v. Date that the leak is repaired;<\/p>\n<p style=\"padding-left: 40px;\">vi. Location of the leak, including the street address or location description, municipality in which the component is located, county, zip code, latitude, and longitude.;<\/p>\n<p style=\"padding-left: 40px;\">vii. If known, the method by which the leak was identified; and<\/p>\n<p style=\"padding-left: 40px;\">viii. If known, the volume of methane emissions released, per unit of time.<\/p>\n<p>4. If applicable, leak detection practices that exceed the minimum requirements of 49 CFR Part 192, Subpart M, as follows:<\/p>\n<p style=\"padding-left: 40px;\">i. Frequency of leak detection surveys;<\/p>\n<p style=\"padding-left: 40px;\">ii. Types of leak detection equipment or technology utilized;<\/p>\n<p style=\"padding-left: 40px;\">iii. Leak prevention and reduction efforts; and<\/p>\n<p style=\"padding-left: 40px;\">iv. Plans to utilize leak detection equipment or technology that exceeds Federal requirements.<\/p>\n<p>5. A report of each blowdown event in excess of 50 standard cubic feet (scf), conducted by a gas public utility, as follows:<\/p>\n<p style=\"padding-left: 40px;\">i. Blowdown identification number;<\/p>\n<p style=\"padding-left: 40px;\">ii. The amount of natural gas released, measured in standard cubic feet, as calculated with one of the following methodologies:<\/p>\n<p style=\"padding-left: 80px;\">(1) The volume of the pipeline segment between isolation valves and the pressure and the temperature of the gas within the pipeline in accordance with 40 CFR 98.233(i)2, incorporated by reference; or<\/p>\n<p style=\"padding-left: 80px;\">(2) The measurement of emissions using a flow meter in accordance with 40 CFR 98.233(i)3, incorporated by reference;<\/p>\n<p style=\"padding-left: 120px;\">iii. The percent volume of methane of the natural gas released;<\/p>\n<p style=\"padding-left: 120px;\">iv. Date of the blowdown event;<\/p>\n<p style=\"padding-left: 120px;\">v. Reason for blowdown event;<\/p>\n<p style=\"padding-left: 120px;\">vi. Mitigation efforts to reduce emissions from the blowdown event; and<\/p>\n<p style=\"padding-left: 120px;\">vii. Location of blowdown event, including street address or location description, municipality, county, zip code, latitude, and longitude.<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row full_width=&#8221;stretch_row_content_no_spaces&#8221; css=&#8221;.vc_custom_1677530790009{background-color: #ffffff !important;}&#8221;][vc_column][vc_single_image image=&#8221;1556&#8243; img_size=&#8221;full&#8221;][vc_raw_html]JTNDZGl2JTIwY2xhc3MlM0QlMjJjYXJvdXNlbC1jYXB0aW9uJTIwZC1tZC1ibG9jayUyMGQtc20tYmxvY2slMjIlM0UlMEElMjAlMjAlMjAlMjAlMjAlM0NoMSUzRUdSRUVOSE9VU0UlMjBHQVMlMjBNT05JVE9SSU5HJTIwQU5EJTIwUkVQT1JUSU5HJTIwUlVMRSUzQyUyRmgxJTNFJTBBJTNDJTJGZGl2JTNF[\/vc_raw_html][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1652362115516{background-color: #ffffff !important;}&#8221;][vc_column][breadcrumb-shortcode][vc_custom_heading text=&#8221;Natural Gas Public Utilities with Distribution Systems&#8221; font_container=&#8221;tag:h2|font_size:28|text_align:left|color:%2300669d&#8221; google_fonts=&#8221;font_family:Roboto%3A100%2C100italic%2C300%2C300italic%2Cregular%2Citalic%2C500%2C500italic%2C700%2C700italic%2C900%2C900italic|font_style:500%20bold%20regular%3A500%3Anormal&#8221;][vc_column_text]The Department requires each gas public utility operating within the State, and providing natural gas, to submit an annual Pipeline Modernization Report. Each gas public utility will be required to include three categories of information in [&hellip;]<\/p>\n","protected":false},"author":224,"featured_media":0,"parent":1282,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"fullwidth.php","meta":{"footnotes":""},"class_list":["post-1258","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/deptest.nj.gov\/ghg\/wp-json\/wp\/v2\/pages\/1258","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/deptest.nj.gov\/ghg\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/deptest.nj.gov\/ghg\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/deptest.nj.gov\/ghg\/wp-json\/wp\/v2\/users\/224"}],"replies":[{"embeddable":true,"href":"https:\/\/deptest.nj.gov\/ghg\/wp-json\/wp\/v2\/comments?post=1258"}],"version-history":[{"count":0,"href":"https:\/\/deptest.nj.gov\/ghg\/wp-json\/wp\/v2\/pages\/1258\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/deptest.nj.gov\/ghg\/wp-json\/wp\/v2\/pages\/1282"}],"wp:attachment":[{"href":"https:\/\/deptest.nj.gov\/ghg\/wp-json\/wp\/v2\/media?parent=1258"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}